Ammonia nitrogen degrader
Applications:
1. Purification and treatment of urban domestic sewage;
2. Applicable to all kinds of industrial wastewater, including ink, packaging and printing, auto parts, machinery, painting, surface treatment, paint, paint, electroplating, papermaking, food, printing and dyeing, bleaching and dyeing, leather and other wastewater treatment processes;
Instructions:
1. Small test procedure
Before normal use, a small test experiment can be carried out in the laboratory to confirm the effect and dosage. The method is as follows:
① Measure 200ml of waste water respectively;
② Add ammonia nitrogen treatment agent (such as 100ppm, 200ppm, etc.) in sequence;
③ Stir for about 10 minutes to allow the medicine to fully react;
④ Determination of residual ammonia nitrogen value in water.
2. Field use
[Pharmaceutical configuration]: For engineering use, it can be configured as a 10% solution, which is lifted by the chemical pump;
[Dosage amount]: In general, if 1KG of this product is added to each ton of wastewater, the ammonia nitrogen value can be reduced by about 100mg/L; the specific dosage should be calculated according to the ammonia nitrogen content in the wastewater or determined through a small test.
【Conditions of use】: The pH range of the applicable water is 1-12. It is recommended to add it after biochemical treatment, and the reaction time is about 10 minutes.
Copyright © 2014-2024 Shenzhen JingZhuoKe Chemical Technology co., LTD All Rights Reserved Site map